Aero X100 changelog file Firmware consists of 3 parts: * APP code x100_3_2x_x_enc.aax * LOADER code loader_x100_3_2x_x_enc.aax * BOOT code boot_x100_3_x_x_enc.aax 2023-11-07 app 3.22.8 -update FreeRTOS to v10.4.3-Patch3 -fix MbedTLS CVE-2021-43666 -update cryptoauthlib to v3.5.1 -add configurable OSDP timings loader 3.22.8 -fix MbedTLS CVE-2021-43666 -update cryptoauthlib to v3.5.1 boot 3.22.8 2023-08-25 app 3.22.7 loader 3.22.7 boot 3.22.7 2023-02-15 app 3.22.6 loader 3.22.6 boot 3.22.6 2022-10-03 app 3.22.5 loader 3.22.5 boot 3.22.5 2022-08-04 app 3.22.4 -update FreeRTOS to v10.4.3-Patch2 -update MbedTLS to v2.28.0 -add support for alternate crypto eeprom loader 3.22.4 -update MbedTLS to v2.28.0 -add support for alternate crypto eeprom boot 3.22.4 2022-04-21 app 3.22.3 loader 3.22.3 boot 3.22.3 2022-03-24 app 3.22.2 loader 3.22.2 boot 3.22.2 2022-03-16 app 3.22.1 loader 3.22.1 boot 3.22.1 2020-07-01 app 3.21.13 loader 3.21.13 boot 3.1.1 2020-06-23 app 3.21.12 -fix: do not send back ack for periodic time broadcast from controller to address issue with SIO dropping offline loader 3.21.12 -fix: do not send back ack for periodic time broadcast from controller to address issue with SIO dropping offline boot 3.1.1 2020-05-11 app 3.21.11 - fix: fix X100 Reader LEDs are reversed -fix: mbedTLS disable weak ciphers and hash algorithms loader 3.21.11 -fix: mbedTLS disable weak ciphers and hash algorithms boot 3.1.1 2020-02-07 app 3.21.10 - fix reader loop back test loader 3.21.10 boot 3.1.1 2019-11-26 app 3.21.9 - fix the problem with SIO not keeping OSDP readers online when configuration gets re-downloaded - fix port1=OSDP reader/port0= Wiegand reader, OSDP bus stops polling during Wiegand card read - fix crashing when changing the ictv_num for inputs - fix the bug with OSDP Sec Ch un-padding - fix Suprema Reader not working with latest 1.4 firmware loader 3.21.9 boot 3.1.1 2019-10-23 app 3.21.8 - add 57600, 230400 baud rate support for OSDP - increase priority of piv messages being sent to reader - fix the bug when extended length reply message to re-transmitted command ( this happens when comm error occurs) have incorrect length . - add support for HID certificate chain and signature downloading and verification - disable legacy AES128 encryption loader 3.21.8 boot 3.1.1 2019-06-27 app 3.21.7 -fix the issue when reader in secure channel is not being brought back online after a Reset SCP & re-download of the configuration takes place loader 3.21.7 boot 3.1.1 2019-06-03 app 3.21.6 - fix the issue when ANSSI solution processing two cards at same time gets stuck - add ability to disable OSDP baud rate discovery - disable sending led command periodically for HID readers when (fw is 1.142.0) or (fw is 1.61.0 or higher) - add new command to support turning off/on reader power supply for a defined time loader 3.21.6 boot 3.1.1 2019-05-01 app 3.21.5 -add support for HID Mfg Info: Serial No and UUID loader 3.21.5 boot 3.1.1 2019-03-19 app 3.21.4 -replace WolfSSL with mbedTLS -add reset command for crypto memory chip -add improvements in handling on multiple OSDP readers on a single port loader 3.21.4 -replace WolfSSL with mbedTLS boot 3.1.1 2019-02-08 app 3.21.3 loader 3.21.3 boot 3.1.1 2019-01-17 app 3.21.2 loader 3.21.2 boot 3.1.1 2018-11-16 app 3.21.1 -initial release loader 3.21.1 -initial release boot 3.1.1